Gabriela, Yohana (2021) Evaluasi dan Optimasi IPAL Laundry di Rumah Sakit Kepresidenan RSPAD Gatot Soebroto, Jakarta Pusat. bachelor thesis, Podomoro University.
|
Text (Cover)
24170003_TA_1_Cover.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (13kB) | Preview |
|
|
Text (Surat Bebas Plagiat)
24170003_TA_2_SuratBebasPlagiat.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (458kB) | Preview |
|
|
Text (Halaman Pernyataan Persetujuan Publikasi)
24170003_TA_3_HalamanPengesahan.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (68kB) | Preview |
|
|
Text (Kata Pengantar)
24170003_TA_4_KataPengantar.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (65kB) | Preview |
|
|
Text (Halaman Pernyataan Persetujuan Publikasi)
24170003_TA_5_PersetujuanPublikasi.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (577kB) | Preview |
|
|
Text (Abstrak)
24170003_TA_6_Abstrak.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (44kB) | Preview |
|
|
Text (Daftar Isi)
24170003_TA_7_DaftarIsi.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (97kB) | Preview |
|
|
Text (Daftar Gambar)
24170003_TA_8_DaftarGambar.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (78kB) | Preview |
|
|
Text (Daftar Tabel)
24170003_TA_9_DaftarTabel.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (83kB) | Preview |
|
|
Text (Daftar Lampiran)
24170003_TA_10_DaftrLampiran.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (74kB) | Preview |
|
|
Text (Bab 1)
24170003_TA_11_BAB1.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (111kB) | Preview |
|
Text (Bab 2)
24170003_TA_12_BAB2.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (367kB) | Request a copy |
||
Text (Bab 3)
24170003_TA_13_BAB3.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (154kB) | Request a copy |
||
Text (Bab 4)
24170003_TA_14_BAB4.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (550kB) | Request a copy |
||
Text (Bab 5)
24170003_TA_15_BAB5.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (698kB) | Request a copy |
||
Text (Bab 6)
24170003_TA_16_BAB6.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (37kB) | Request a copy |
||
|
Text (Daftar Pustaka)
24170003_TA_17_DaftarPustaka.pdf Available under License Creative Commons Attribution Non-commercial Share Alike. Download (161kB) | Preview |
|
Text (Lampiran)
24170003_TA_18_Lampiran.pdf Restricted to Repository staff only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (3MB) | Request a copy |
Abstract
Instalasi Pengolahan Air Limbah (IPAL) Laundry Rumah Sakit Kepresidenan RSPAD Gatot Soebroto telah beroperasi sejak tahun 2005. Berkaitan pada rencana penambahan debit air buangan dari kegiatan dapur dan laundry RSPAD menuju IPAL Laundry, kegiatan evaluasi dilakukan dalam mengetahui kesesuaian desain serta meningkatkan kapasitas IPAL Laundry sehingga kinerja pengolahan lebih optimal. IPAL ini dibangun dengan teknologi lumpur aktif tipe extended aeration dengan kapasitas IPAL saat ini adalah 50 m3/hari dengan debit air buangan per hari eksisting 13 m3/hari. Estimasi kuantitas dan karakteristik dari air buangan dapur serta laundry dilakukan berdasarkan hasil pemeriksaan lapangan dan studi literatur. Pengambilan sampel air juga dilakukan pada influen dan efluen dengan parameter BOD, COD, TSS. Setelah itu dilakukan perhitungan kesesuaian kriteria desain. Hasil evaluasi estimasi debit influen pada masa yang akan datang adalah 67 m3/hari. Evaluasi terhadap kinerja IPAL saat ini menunjukkan penyisihan BOD 17,87%, COD 53,88% dan TSS 22,91%. Rekomendasi optimalisasi yang diberikan berupa perubahan sistem pengolahan dari extended aeration menjadi conventional activated sludge, penyesuaian dimensi pada bak ekualisasi, bak pengendap awal, bak aerasi dan bak sedimentasi. Menambahkan pompa lumpur agar sistem resirkulasi dapat berjalan dengan baik dan blower sebagai suplai oksigen tercukupi serta melakukan perbaikan pada SOP IPAL.
Item Type: | Thesis (bachelor) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Contributors (Pembimbing): |
|
||||||||||||
Uncontrolled Keywords: | Evaluasi, lumpur aktif, rumah sakit, Instalasi Pengolahan Air Limbah | ||||||||||||
Subjects: | Environmental Engineering | ||||||||||||
Divisions: | Prodi Teknik Lingkungan | ||||||||||||
Depositing User: | Kurnia Sholihah | ||||||||||||
Date Deposited: | 09 Feb 2021 08:45 | ||||||||||||
Last Modified: | 10 Feb 2021 07:35 | ||||||||||||
URI: | http://repository.podomorouniversity.ac.id/id/eprint/423 |
Actions (login required)
View Item |